New Holland 18004 – Armrest: Hand Throttle #2 - Voltage Too High

Issue description

The hand throttle #2 is reporting a voltage that is higher than expected, which may indicate a fault in the electrical signal or the component itself.

Check the cause

  1. Hand throttle #2

  2. the affected circuit

Repair steps

  1. Inspect

    Inspect the hand throttle #2 for physical damage or wear that could cause an abnormal voltage reading.

  2. Test

    Test the voltage output of the hand throttle #2 using a multimeter to confirm the reading is indeed too high.

  3. Check

    Check the wiring and connections related to the hand throttle #2 for any loose, damaged, or corroded components.