18017

New Holland 18017 – New Holland Armrest Control Unit: Rear hitch draft control potentiometer – voltage too high

Issue description

The rear hitch draft control potentiometer is reporting a voltage that is higher than expected. This may affect the proper operation of the hitch system.

Check the cause

  1. Rear hitch draft control potentiometer

  2. the affected circuit

Repair steps

  1. Inspect

    Inspect the rear hitch draft control potentiometer for physical damage or wear.

  2. Test

    Test the voltage output of the rear hitch draft control potentiometer using a multimeter.

  3. Check

    Check the wiring and connections to the rear hitch draft control potentiometer for any loose or damaged components.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote