New Holland 18024 – ACM: EHR Flow Encoder Position Error
Issue description
The Armrest Control Module (ACM) has detected an error in the position of the EHR flow code sensor, which is associated with the remote control valve. This indicates a potential issue with the sensor's alignment or functionality relative to the remote control valve. The signal from the encoder (potentiometer) that informs the control module of the desired hydraulic flow rate is not what the system expects, likely due to an incorrect voltage reading or a complete loss of signal.
Applies to these machines
71 machines- T4.80F
- T4.90F
- T4.100F
- T4.110F
- T4.80LP
- T4.90LP
- T4.100LP
- T4.110LP
- T4.80N
- T4.80V
- T4.90N
- T4.90V
- T4.100N
- T4.100V
- T4.110N
- T4.110V
- T6030
- T6050
- T6070
- T6080
- T6090
- T6.140
- T6.145
- T6.150
- T6.155
- T6.160
- T6.165
- T6.175
- T7.170
- T7.185
- T7.200
- T7.210
- T7.220
- T7.235
- T7.250
- T7.260
- T7.270
- T7.175
- T7.190
- T7.225
- T7.230
- T7.245
- T7.290
- T7.315
- T7030
- T7040
- T7050
- T7060
- T7070
- T8.275
- T8.300
- T8.320
- T8.330
- T8.350
- T8.360
- T8.390
- T8.410
- T8.420
- T8.435
- T9.435
- T9.450
- T9.480
- T9.505
- T9.530
- T9.560
- T9.565
- T9.600
- T9.615
- T9.645
- T9.670
- T9.700
Check the cause
Verify the fault code 18024 is active using the tractor's diagnostic menu or an Electronic Service Tool (EST)
Check for other active fault codes, especially those related to the ACM, CAN bus communication, or power supply, as these can trigger secondary faults
Check the power supply voltage to the Armrest Control Module to ensure it is receiving correct voltage
Inspect the wiring harness and connectors leading to and within the armrest console for chafing, pinching, corrosion, or broken wires near the plug
Test the suspected 3-wire EHR flow encoder potentiometer with a multimeter (measure for fixed resistance between outer terminals, and smooth resistance change between the center wiper and outer terminal while turning the knob)
Repair steps
Prepare machine for service
Park the tractor on a level surface, lower all implements, turn off the engine, and disconnect the battery before working on electrical components.
Access armrest internals
Disassemble the armrest console to gain access to the electronic components, including the EHR flow control knobs.
Identify faulty component
Locate the specific EHR flow encoder/potentiometer associated with the fault (the knob controlling the affected remote valve).
Replace potentiometer
If diagnostic tests confirm the potentiometer is faulty, replace it with a new EHR Flow Control Knob Potentiometer.
Reassemble and restore power
Reassemble the armrest console, reconnect the battery, and turn on the ignition.
Clear fault codes
Use the tractor's diagnostic system or an EST to clear the fault codes.
Perform functional test
Operate the hydraulic remote controlled by the new potentiometer to ensure it is functioning correctly. Check for smooth and proportional control of the hydraulic flow.
Calibration
Perform a calibration of the new component if required by the system, typically done through the tractor's diagnostic menu or with an EST.
Parts you might need
(10)EHR Flow Control Knob Potentiometer
87663294Alternative part number 87755846. Located on the electronic draft control section of the armrest unit.
- Rexroth Remote Valve84125295
For Case New Holland Tractor
Hydraulic Remote Valve
86018023Fits New Holland 8670, 8770, 8870, 8970
Fits New Holland 8670, 8770, 8870, 8970
Rear Remote Hydraulic Valve Kit
MT20116103Verify fitment by serial number
- Potentiometer87605247
Potential part number for the armrest control potentiometer. Verify correct part number with an authorized dealer using the tractor's serial number.
Diagnostic Switch
380000843Required to access the H-menu diagnostic mode for calibration.
- Standard Pilot Head Valve47643919
Fits various T7, T8, and T9 series tractors. Supersedes 84139664, 84173128, 84478195, and 87577686.
- Pilot Valve Head48138887
Listed for New Holland T7 models.
- Pilot Head Valve Assembly47735860
Listed for T7.260 and T7.270 models.
Get help to fix this fault by requesting a quote