New Holland 18045 – Armrest Control Module: EHR Lever Position (Remote Control Valve) 3 - Too High Voltage
Issue description
The controller is receiving a signal voltage from the Electro-Hydraulic Remote (EHR) valve #3 control lever that exceeds the normal operating range (typically above 4.5V - 4.8V). This condition is almost always caused by an internal failure of the lever's potentiometer, a short to a power source (5V or 12V) in the signal wire, or an open ground circuit on the lever's sensor loop.
Applies to these machines
29 machines- T4.80F
- T4.90F
- T4.100F
- T4.110F
- T6.140
- T6.155
- T6.175
- T7.170
- T7.185
- T7.200
- T7.210
- T7.220
- T7.270
- T8.275
- T8.300
- T8.330
- T8.360
- T8.390
- T8.420
- T9 Series
- SP.300F
- SP.400F
- E70
- E80
- EH70
- EH80
- EH130
- EH160
- EH215
Check the cause
Inspect the wiring harness and connectors leading to the armrest controller for chafing, pinching, or breaks.
Check for internal wire breaks near the plug by gently pulling on each wire to see if it stretches.
Test the 3-wire potentiometer functionality with a multimeter to check for an internal short or failure.
Check the tractor's diagnostic display for other active fault codes, such as communication errors (e.g., code 4100) or power supply issues that could trigger this fault.
Repair steps
Attempt Recalibration
Access the 'H' menu on the tractor's display and navigate to the armrest or auxiliary lever calibration menu (may be listed as 'AUX LEVER'). Follow the on-screen prompts to move the lever to its full extend, retract, and neutral positions. Clear the fault code and test.
Replace Potentiometer or Lever Assembly
If recalibration fails, disassemble the armrest control panel and replace the faulty potentiometer. If the potentiometer is integrated into the EHR lever or switch assembly, replace the entire unit.
Replace Armrest Control Module
If the sensor and wiring are functional and the fault persists, the issue may be internal to the control module's circuitry. Replace the Armrest Control Module as a last resort.
Perform Post-Replacement Calibration
After replacing any components, recalibrate the armrest controls so the system recognizes the new component's voltage range.
Parts you might need
(18)EHR Flow Control Potentiometer
87663294Located on the electronic draft control section of the armrest.
- EHR Flow Control Potentiometer87755846
Alternative part number for the EHR flow control knob potentiometer.
- Potentiometer (Generic/Excavator)YN52S00032P1
Listed for New Holland excavators but may be used in other applications with similar control systems.
Potentiometer (Generic/Excavator)
YN52S00032P3Listed for New Holland excavators but may be used in other applications with similar control systems.
Potentiometer (Sprayer)
21.42292Listed for various New Holland sprayers.
Armrest Control Module
47443335Replace only if fault is internal to the module.
- Armrest Control Module48068689
Replace only if fault is internal to the module.
- Armrest Control Module84206614
Replaced by 48068689. Replace only if fault is internal to the module.
Electro-Hydraulic Remote (EHR) Control Lever
87613723Standard Control Lever
Electro-Hydraulic Remote (EHR) Control Lever
87613726Control Lever - Black
- Complete pod assembly82024131
Complete pod assembly for older models like TM or T7000 series
Arm Rest Control Unit Potentiometer/Switch
87660885For T6 and T7 series tractors.
- Potentiometer87605247
For T7030, T6.140, and T7050. Supersedes: 82012603, 82017351, 82021036, 82033385, 87559692, 82010303.
General OEM Potentiometer
86729675General OEM potentiometer for New Holland equipment.
Electronic Control Unit for Armrest
48068685ECU for Armrest Control Module
Armrest Control Panel/Assembly
84366982For T9 series
Electronic Armrest Lift/EHR Control
87648539For T6000 Series
- Armrest Assembly86502167
General armrest assembly
Get help to fix this fault by requesting a quote