18056

New Holland 18056: Control Lever 2, X-axis - Increased Voltage

Issue description

The system has detected an increased voltage in the X-axis of Control Lever 2. This may indicate a fault in the electrical signal or the component associated with this lever.

Check the cause

  1. The wiring and connections related to Control Lever 2

  2. The signal output from Control Lever 2

  3. The circuit associated with the X-axis of Control Lever 2

Repair steps

  1. Inspect

    Inspect the wiring and connections for Control Lever 2 for damage, wear, or loose connections.

  2. Test

    Test the signal output from Control Lever 2 using a multimeter or diagnostic tool.

  3. Check

    Check the circuit associated with the X-axis of Control Lever 2 for faults or irregularities.