1809

New Holland 1809 – ENGINE: Burner Glow Voltage: Abnormal High

Issue description

The system has detected an abnormal high voltage in the burner glow circuit. This condition may affect the proper operation of the burner and could indicate a fault in the associated electrical components.

Check the cause

  1. Burner Glow Circuit

  2. Voltage Supply to Burner Glow Component

Repair steps

  1. Inspect

    Check the wiring and connections related to the burner glow circuit for damage, corrosion, or loose connections.

  2. Test

    Use a multimeter to measure the voltage at the burner glow component and compare it to the expected range specified in the service manual.

  3. Verify

    Ensure that the component identified by this code is functioning correctly and is not causing the abnormal voltage reading.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other New Holland codes