19002
New Holland 19002 – New Holland Dosing Control Unit Dcu: Battery Voltage Sensing – Signal Low
Issue description
The system has detected a low battery voltage signal, indicating that the battery voltage evaluation is below the lower limit. This may affect the proper operation of the electrical system.
Check the cause
Battery voltage levels
Battery connections
Voltage sensing circuit
Repair steps
Check battery voltage
Use a multimeter to measure the battery voltage and confirm if it is below the expected range.
Inspect battery connections
Verify that all battery terminals and connections are clean, tight, and free from corrosion.
Test voltage sensing circuit
Check the integrity of the voltage sensing circuit for any faults or disruptions.
Parts you might need
(0)Get help to fix this fault by requesting a quote