19002

New Holland 19002 – New Holland Dosing Control Unit Dcu: Battery Voltage Sensing – Signal Low

Issue description

The system has detected a low battery voltage signal, indicating that the battery voltage evaluation is below the lower limit. This may affect the proper operation of the electrical system.

Check the cause

  1. Battery voltage levels

  2. Battery connections

  3. Voltage sensing circuit

Repair steps

  1. Check battery voltage

    Use a multimeter to measure the battery voltage and confirm if it is below the expected range.

  2. Inspect battery connections

    Verify that all battery terminals and connections are clean, tight, and free from corrosion.

  3. Test voltage sensing circuit

    Check the integrity of the voltage sensing circuit for any faults or disruptions.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other New Holland codes