1901
New Holland 1901 – UCM: High Voltage in UCM Power Supply
Issue description
The UCM has detected a high voltage condition in the power supply. This may indicate an overvoltage situation that could affect the proper operation of the system.
Check the cause
Power supply voltage levels
Voltage regulation components
Connections to the UCM
Repair steps
Measure the voltage at the UCM power supply input
Use a multimeter to verify the voltage level and ensure it is within the specified range.
Inspect the power supply connections
Check for loose, damaged, or corroded connections that may cause voltage irregularities.
Verify the functionality of the voltage regulation components
Test the components responsible for regulating the power supply voltage to ensure they are operating correctly.
Parts you might need
(0)Get help to fix this fault by requesting a quote