1901

New Holland 1901 – VCM: VCM Supply Voltage High White

Issue description

The Vehicle Control Module (VCM) has detected a supply voltage that is above the normal operating range, indicating an electrical overvoltage condition. This situation can affect the VCM's operation and is typically caused by a malfunction in the machine's charging system, such as an alternator overcharging the system beyond 15 to 16 volts. The 'White' indicator suggests a warning-level fault.

Applies to these machines

  • L190
  • L218
  • L220
  • L223
  • L230
  • LS180

Check the cause

  1. Verify battery voltage with the engine off (should read approximately 12.6 volts)

  2. Measure charging system voltage across the battery terminals with the engine running at normal operating RPM (normal is 13.5 to 14.7 volts; readings above 14.7V indicate overcharging)

  3. Inspect battery terminals for looseness or corrosion, cleaning and tightening as necessary

  4. Check the main power and ground connections to the VCM and the alternator to ensure they are clean, tight, and free of damage

  5. Inspect the alternator's sense wire connection (a loose or corroded sense wire can cause the regulator to misread battery voltage and overcharge)

Repair steps

  1. Confirm overcharging

    Based on the diagnostic voltage checks, confirm that the alternator is producing excessive voltage (above 14.7 volts).

  2. Isolate the cause

    Determine if the overcharging is caused by a faulty internal voltage regulator (most common) or a faulty diode rectifier within the alternator.

  3. Replace faulty component

    Replace the voltage regulator (if serviceable separately) or the entire alternator assembly. After replacement, run the engine and verify the charging voltage is within the correct 13.5-14.7 volts range.

  4. Clear fault codes

    Once the charging system is functioning correctly and voltage is normal, clear the fault codes from the VCM to ensure code 1901 does not reappear.

Parts you might need

(6)
  • Alternator

    OEM part number varies by machine model and serial number. Use official New Holland parts catalogs for lookup.

  • Voltage Regulator

    May be integrated into the alternator or available separately depending on the model.

  • Vehicle Control Module (VCM)

    SBA185186180

    Listed for L218, L220. Only replace if damaged by prolonged overvoltage.

  • Vehicle Control Module (VCM)

    SBA185186181

    Listed for L218, L220. Only replace if damaged by prolonged overvoltage.

  • Vehicle Control Module (VCM)

    84472188

    Replaced by 5801459462. Only replace if damaged by prolonged overvoltage.

  • Replacement for 84472188. Only replace if damaged by prolonged overvoltage.