1905

New Holland 1905 – UCM: 5VREF1 Sensor Supply Voltage Out of Range

Issue description

The Universal Control Module (UCM) has detected that the 5-volt reference signal number 1 (5VREF1) is outside its specified range of 4.8 to 5.2 volts. This reference line provides power to multiple sensors. An out-of-range voltage can be caused by a short to ground, a short to another power source, a faulty sensor on the circuit, a wiring harness issue, or a malfunction within the UCM itself. When active, this is a 'Red' priority error that disables all machine hydraulics as a safety precaution.

Applies to these machines

  • L218
  • L220
  • L221
  • L223
  • L225
  • L230
  • C227
  • C232
  • C238
  • TR320
  • TV380
  • SR220
  • SR250
  • SV250
  • SV300

Check the cause

  1. Verify the fault code using an Electronic Service Tool (EST) and check for other active codes.

  2. Ensure the battery is fully charged and terminals are clean and tight, as a flat or recently jump-started battery can trigger this code.

  3. Check battery voltage while the engine is running (should be stable between 13.7 and 14.5 volts) and inspect all related fuses.

  4. Thoroughly inspect wiring harnesses and connectors associated with the UCM and sensors for damage, corrosion, abrasion, or improper connections.

  5. Measure voltage at the UCM connector X-CN1A pin 8 to chassis ground with the ignition ON. If the voltage is between 4.8V and 5.2V, the issue may be intermittent (consider reprogramming the UCM); if below 4.8V or above 5.2V, proceed to the repair procedure.

Repair steps

  1. Isolate the UCM

    Turn ignition OFF, disconnect UCM connector X-CN1A, and turn ignition ON. Measure voltage between pin 8 on the harness side and chassis ground. If greater than 0.5V, repair the short circuit to another power source in the harness.

  2. Check for short to ground

    With ignition OFF and UCM disconnected, measure resistance between pin 8 on the harness side and chassis ground. It should be greater than 20,000 Ω. Low resistance indicates a short to ground in the wiring or a connected sensor.

  3. Isolate faulty sensors

    Keep UCM disconnected and disconnect all sensors on the 5VREF1 circuit (e.g., Throttle Position Sensor, Right-hand control handle/joystick, EHF pressure transducer, Universal Joystick Module). Repeat the resistance check on pin 8. If resistance is now high, reconnect sensors one at a time until the resistance drops or voltage goes out of range to identify the faulty component. Temporarily replace the faulty sensor and re-test.

  4. Reprogram or replace UCM

    If no fault is found in the wiring or sensors, the UCM is likely faulty. Have the UCM reprogrammed with the latest software by a certified dealer. If unresolved, replace the UCM (requires dealer programming).

Parts you might need

(11)
  • Universal Control Module (UCM)

    84529539

    Alternate part number 47395504. Requires dealer programming before use.

  • OEM Throttle Position Sensor.

  • Foot Throttle with Sensor

    47414005

    Fits models including L218, L220, C227, C238, SR220, SV250, TR320, TV380.

  • For some forage harvesters.

  • Throttle Control

    47409019

    OEM Throttle Control.

  • Potential component on the 5VREF1 circuit.

  • Fits models including L218, L220, C227, C232, C238.

  • Potential component on the 5VREF1 circuit.

  • OEM part. Alternate compatible part numbers include 47395504R (remanufactured), 84267444, and 47385274. Verify fitment by serial number.

  • Universal Control Module (UCM) / Electronic Control Unit (ECU)

    84348127R

    Remanufactured version

Get help to fix this fault by requesting a quote

Browse other New Holland codes