New Holland 19055: Reagent Temperature Sensor of Pump Module - Short Circuit High

Issue description

The fault code indicates a short circuit high in the reagent temperature sensor of the pump module. This suggests an electrical fault in the sensor circuit, which may affect the proper functioning of the system.

Check the cause

  1. The wiring and connections of the reagent temperature sensor of the pump module

  2. The integrity of the sensor itself

  3. The circuit associated with the reagent temperature sensor of the pump module

Repair steps

  1. Inspect

    Inspect the wiring and connections of the reagent temperature sensor of the pump module for damage, corrosion, or loose connections.

  2. Test

    Test the reagent temperature sensor of the pump module for continuity and resistance using a multimeter, following the service manual guidelines.

  3. Replace

    If the sensor is found to be faulty, replace the reagent temperature sensor of the pump module with a compatible part.