New Holland 19055: Reagent Temperature Sensor of Pump Module - Short Circuit High
Issue description
The fault code indicates a short circuit high in the reagent temperature sensor of the pump module. This suggests an electrical fault in the sensor circuit, which may affect the proper functioning of the system.
Check the cause
The wiring and connections of the reagent temperature sensor of the pump module
The integrity of the sensor itself
The circuit associated with the reagent temperature sensor of the pump module
Repair steps
Inspect
Inspect the wiring and connections of the reagent temperature sensor of the pump module for damage, corrosion, or loose connections.
Test
Test the reagent temperature sensor of the pump module for continuity and resistance using a multimeter, following the service manual guidelines.
Replace
If the sensor is found to be faulty, replace the reagent temperature sensor of the pump module with a compatible part.
Parts you might need
(0)Get help to fix this fault by requesting a quote