19058

New Holland 19058: UREA Temperature Sensor Signal Out of Range

Issue description

The UREA temperature sensor in block is reporting a signal value that is below the lowest error threshold and is outside the allowable range. This indicates a potential issue with the sensor's ability to provide accurate temperature readings.

Check the cause

  1. The UREA temperature sensor in block for proper connection and physical integrity

  2. The wiring and harness associated with the UREA temperature sensor in block

  3. The power supply and ground connection for the UREA temperature sensor in block

Repair steps

  1. Inspect

    Inspect the UREA temperature sensor in block for damage, corrosion, or loose connections.

  2. Test

    Test the UREA temperature sensor in block using a multimeter to verify its output signal against expected values.

  3. Replace

    If the UREA temperature sensor in block is found to be faulty, replace it with a compatible replacement.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other New Holland codes