1906

New Holland 1906 – VCM: 5Vref3 Sensor Supply Voltage Out Of Range

Issue description

The Vehicle Control Module (VCM) or Universal Control Module (UCM) has detected that the 5-volt reference voltage supplied to a specific group of sensors (5Vref3) is outside its normal operating range of 4.8 to 5.2 volts. This indicates a potential issue with the power supply, the electrical circuit, or the sensors themselves. This is considered a 'Red' priority error, and as a result, all hydraulics on the machine are disabled while the fault is active.

Applies to these machines

  • C232
  • Skid Steer Loaders (SSL)
  • Compact Track Loaders (CTL)

Check the cause

  1. Verify Battery and Grounds: Ensure the battery is fully charged and load-tested. Poor battery voltage or faulty ground connections can cause various electrical faults.

  2. Inspect Wiring and Connectors: Check the wiring harness and connectors associated with the UCM, right-hand control handle, and Universal Joystick Module for any signs of damage, corrosion, abrasion, or loose connections.

  3. Check for Active Fault: Confirm that the fault code is currently active.

Repair steps

  1. Initial Verification

    Turn the ignition on to see if the fault code is active. If it is, proceed to the next step.

  2. Harness and Connector Inspection

    Carefully inspect the UCM connectors and the associated wiring harness for any physical damage, corrosion, or improper connections. Repair or replace the affected parts. If the harness and connectors appear to be in good condition, proceed to the next step.

  3. Voltage Measurement at the UCM

    With the ignition switch on, measure the voltage between pin 9 of the UCM connector X-CN1A and the chassis ground. If the voltage is within the 4.8 V to 5.2 V range, the issue may lie with the sensor or the wiring to the sensor. If the voltage is outside this range, the problem is likely within the UCM itself.

  4. Final Confirmation

    After performing repairs, clear the fault codes and turn the ignition on to confirm that fault 1906 does not reappear.

Parts you might need

(5)
  • Sensor87612475

    Generic New Holland sensor, verify fitment by serial number

  • Sensor84421822

    Noted as no longer available, replacement may be needed

  • Sensor87482353

    Generic New Holland sensor, verify fitment by serial number

  • Sensor86523197

    Replaces 84597736

  • Sensor86987513

    Generic New Holland sensor, verify fitment by serial number

Get help to fix this fault by requesting a quote

Browse other New Holland codes