19075

New Holland 19075 – DCU: Voltage Supply 2 - Tube Heaters (UB2) Electrical Short Circuit to Ground

Issue description

The fault code indicates an electrical short circuit to ground in the voltage supply for the 2-tube heaters (UB2). This issue affects the reagent suction tube heating system, specifically a short circuit on the low side.

Check the cause

  1. The wiring and connections related to the voltage supply for the 2-tube heaters (UB2)

  2. The reagent suction tube heating component for signs of damage or shorting

  3. The grounding points associated with the voltage supply system

Repair steps

  1. Inspect

    Inspect the wiring and connections for the voltage supply to the 2-tube heaters (UB2) for any signs of damage, wear, or improper connections.

  2. Test

    Test the reagent suction tube heating component for continuity and insulation resistance to identify any internal short circuits.

  3. Check

    Check the grounding points of the voltage supply system to ensure they are secure and free from corrosion or damage.