19091

New Holland 19091 – New Holland Dosing Control Unit Dcu: Low 12 Volt Supply for Dosing Module

Issue description

The system has detected a low 12 volt supply for the dosing module. This may affect the operation of the dosing valve or pump motor due to insufficient power.

Check the cause

  1. Power supply to the dosing module

  2. Connections and wiring related to the 12 volt supply

  3. Voltage levels at the dosing module

Repair steps

  1. Check the power supply to the dosing module

    Verify that the 12 volt supply is properly connected and functioning.

  2. Inspect the wiring and connections

    Look for any loose, damaged, or corroded connections related to the 12 volt supply.

  3. Measure the voltage at the dosing module

    Use a multimeter to confirm that the voltage is within the acceptable range as specified in the service manual.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other New Holland codes