New Holland 19091: Low Power Supply Voltage for Metering Module

Issue description

The system has detected a low power supply voltage for the metering module. This may affect the operation of the metering valve or electric motor pump. The fault is related to the 12 V supply for the metering module not reaching the lower limit value.

Check the cause

  1. The 12 V supply for the metering module

  2. The power supply connections to the metering module

  3. The voltage level at the metering module

Repair steps

  1. Check the 12 V supply for the metering module

    Verify that the power supply is providing the correct voltage to the metering module.

  2. Inspect the power supply connections

    Check for loose, damaged, or corroded connections related to the 12 V supply.

  3. Measure the voltage at the metering module

    Use a multimeter to measure the voltage at the metering module to confirm it meets the required specifications.