19101

New Holland 19101 – New Holland Dosing Control Unit Dcu: Urea level sensor (electrical) – signal high – P203D reagent – tank level sensor – short circuit high

Issue description

The system has detected a high signal from the urea level sensor, indicating a potential short circuit in the reagent tank level sensor circuit.

Check the cause

  1. The urea level sensor wiring and connections

  2. The reagent tank level sensor for physical damage or short circuit

  3. The electrical continuity of the sensor circuit

Repair steps

  1. Inspect

    Check the wiring and connections of the urea level sensor for damage, corrosion, or loose connections.

  2. Test

    Use a multimeter to test the electrical continuity of the reagent tank level sensor circuit.

  3. Replace

    If a short circuit is confirmed, replace the affected component identified by this code.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other New Holland codes