19109

New Holland 19109: Urea Temperature Sensor in Tank - High Signal Level

Issue description

The urea temperature sensor in the tank is reporting a high signal level. This is likely due to a short circuit to a high voltage source. The affected circuit is causing an abnormal reading from the tank temperature sensor for the reagent solution.

Check the cause

  1. The wiring and connections of the urea temperature sensor in the tank

  2. The integrity of the sensor itself for damage or short circuit

  3. The presence of any moisture or foreign material affecting the sensor or its wiring

Repair steps

  1. Inspect

    Visually inspect the wiring and connections of the urea temperature sensor in the tank for damage, wear, or signs of a short circuit.

  2. Test

    Use a multimeter to test the sensor and its wiring for continuity and resistance, ensuring there is no short to a high voltage source.

  3. Clean or Replace

    If damage or contamination is found, clean or replace the sensor and its wiring as necessary.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other New Holland codes