New Holland 19109: Reagent Tank Temperature Sensor Short Circuit High
Issue description
The fault code indicates a short circuit high in the reagent tank temperature sensor, which measures the temperature of the reagent solution in the tank. This condition suggests an electrical fault in the sensor or its wiring.
Check the cause
The wiring and connections of the reagent tank temperature sensor
The integrity of the reagent tank temperature sensor itself
Repair steps
Inspect
Inspect the wiring and connections of the reagent tank temperature sensor for damage, corrosion, or loose contacts.
Test
Test the reagent tank temperature sensor for continuity and resistance using a multimeter, following the service manual procedures.
Replace
If the sensor or wiring is found to be faulty, replace the affected component as specified in the service manual.