19110

New Holland 19110: Reagent Tank Temperature Sensor Short Circuit Low

Issue description

The fault code indicates a short circuit low in the reagent tank temperature sensor, which measures the temperature of the reagent solution in the tank. This condition may affect the accurate monitoring of the reagent temperature.

Check the cause

  1. The wiring and connections of the reagent tank temperature sensor

  2. The integrity of the sensor itself for physical damage or short circuit

  3. The circuit associated with the reagent tank temperature sensor

Repair steps

  1. Inspect

    Inspect the wiring and connections of the reagent tank temperature sensor for damage, corrosion, or loose connections.

  2. Test

    Test the reagent tank temperature sensor for continuity and resistance using a multimeter, following the service manual guidelines.

  3. Replace

    If a fault is detected, replace the reagent tank temperature sensor with a compatible part.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other New Holland codes