19154

New Holland 19154 – DCU: Reagent Pump Not Delivering

Issue description

The reagent (DEF) pump is not delivering fluid as expected. The Dosing Control Unit (DCU) has commanded the pump to activate but detected inadequate performance. This indicates the pump may be running too slowly, failing to build adequate pressure within the specified time, or drawing an incorrect amount of electrical current due to a blockage, internal wear, or a partial electrical issue.

Applies to these machines

  • T8.275
  • T8.320
  • T8.350
  • T8.380
  • T8.410
  • T8.435
  • T7 Series
  • FR Series

Check the cause

  1. Check DEF quality and level using a refractometer to verify urea concentration is at 32.5%.

  2. Visually inspect the entire DEF system (tank, lines, pump, and injector nozzle) for leaks or white crystal buildup.

  3. Inspect the reagent pump filter inside the pump module for clogs, black/slimy residue, or white crystals (most common mechanical cause).

  4. Listen to the pump during an 'Active Pump' diagnostic test; it should make a steady, high-pitched humming sound, not a weak, intermittent, or grinding noise.

  5. Inspect the electrical harness and connectors leading to the DEF pump for damage, corrosion, or loose connections.

Repair steps

  1. Replace reagent pump filter

    Remove the cap on the pump body and replace the small internal filter of the pump module, as this is a frequent and low-cost failure point.

  2. Flush the DEF system

    If the DEF was found to be contaminated or heavily crystallized during inspection, drain the tank, flush it with distilled or deionized water, and refill with fresh, certified DEF.

  3. Replace reagent pump module

    If the filter has been replaced and the pump still fails to perform (e.g., makes grinding noises or fails to build pressure), replace the entire reagent pump/supply module.

  4. Clear codes and verify

    Use a diagnostic scanner to clear fault code 19154. Perform a drive cycle or run an SCR system verification test to ensure the system is operating correctly and the fault does not return.

Parts you might need

(2)
  • OEM New Holland part (supersedes 47565939, 5802513624, and 5802698300). Remanufactured part number is 5802855463R. Bosch part number 0 444 042 256 (Bosch Denoxtronic 2.2).

  • Reagent Pump Filter

    Internal filter for the pump module.

Get help to fix this fault by requesting a quote