New Holland 19154 – DCU: Pump Speed - Engine Pump Disconnected - Pump Does Not Supply Reagent P208B
Issue description
The Dosing Control Unit (DCU) has detected a problem with the Diesel Exhaust Fluid (DEF) pump's operation. The pump is either not running, running at the wrong speed, or failing to deliver the required amount of DEF to the exhaust system. This can be caused by the pump motor being electrically disconnected, a blockage in the pump motor, a defect in the pump's internal Hall effect sensors, issues with the wiring or electrical connectors, a general failure of the reductant pump itself, or a fault within the Powertrain Control Module (PCM) or DCU.
Applies to these machines
20 machines- T6.125
- T6.160
- T7.165
- T7.190
- T8.320
- TS6.130
- 7030L
- 9080N
- 9090X
- WD1504
- WD2105
- Speedrower 160
- Speedrower 220
- Speedrower 260
- LM6.35
- TH7.42
- SP310F
- Stackcruiser 102
- Stackcruiser 103
- Stackcruiser 105
Check the cause
Visually inspect the DEF pump, its wiring harness, and all related connectors for any signs of damage, corrosion, or loose connections.
Verify that the DEF pump is receiving the correct voltage to rule out an electrically disconnected pump motor.
With the system activated, listen to the pump for a steady hum; unusual noises like a grinding sound can indicate a failing pump.
Check the DEF tank to ensure it is not empty and that the fluid is not contaminated or crystallized.
Inspect the DEF pump's filter for blockages from crystallized DEF or other contaminants.
Repair steps
Connect a Diagnostic Tool
Use a compatible diagnostic tool, such as New Holland EST or Jaltest, to confirm the presence of fault code 19154 and any other related SCR system faults.
Perform Diagnostic Checks
Carry out the diagnostic checks listed above.
Address Electrical Issues
If any wiring or connector faults are found, repair or replace the damaged components. Ensure all connections are clean and secure.
Replace the DEF Filter
If the filter is found to be clogged, replace it. This is a common and relatively inexpensive first step.
Test the Pump
If possible with the available diagnostic tool, perform an active test on the DEF pump to check if it runs and builds pressure.
Replace the DEF Pump/Supply Module
If the diagnostic checks point to a failed pump (e.g., it doesn't run, is noisy, or fails to build pressure), the DEF pump/supply module will need to be replaced.
Clear Fault Codes
After the repair is complete, use the diagnostic tool to clear the fault codes from the DCU.
Verify the Repair
Perform a system verification test, which may involve running the engine through specific cycles to ensure the SCR system is functioning correctly and the fault code does not reappear.
Parts you might need
(2)- DEF Pump / Supply Module5802513621
OEM New Holland/Case IH part. Alternate OEM numbers: 84246892, 47565934, 51515745, 51603476, 5802698090, 84349041.
DEF Pump / Supply Module (Bosch)
0444042210Bosch cross-reference. Alternate Bosch numbers: 0444042088, 0444042146, 0444042253, 0444022021.
Get help to fix this fault by requesting a quote