New Holland 19154 – New Holland Dosing Control Unit Dcu: Urea Pump Speed – Pump Motor Unplugged – P208B Reagent-Pump Not Delivering
Issue description
The urea pump speed is not functioning as expected. The pump motor is unplugged, and the reagent-pump is not delivering the expected output. This condition is indicated by the fault code.
Check the cause
The connection of the pump motor
The wiring to the pump motor
The power supply to the pump motor
Repair steps
Inspect
Inspect the connection of the pump motor for any signs of disconnection or damage.
Test
Test the wiring to the pump motor for continuity and proper functionality.
Verify
Verify the power supply to the pump motor to ensure it is receiving the correct voltage.
Parts you might need