19156

New Holland 19156 – New Holland Dosing Control Unit Dcu: Urea Pump Speed – Pump Overspeed

Issue description

The urea pump is operating at a speed that exceeds the expected range, which may indicate a malfunction in the system controlling the pump's operation.

Check the cause

  1. The urea pump speed sensor

  2. The wiring and connections to the urea pump

  3. The control signals from the dosing control unit

Repair steps

  1. Inspect

    Inspect the urea pump speed sensor for damage or misalignment.

  2. Check

    Check the wiring and connections to the urea pump for continuity and proper seating.

  3. Verify

    Verify the control signals from the dosing control unit to the urea pump using the appropriate diagnostic tool.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other New Holland codes