New Holland 19156 – New Holland Dosing Control Unit Dcu: Urea Pump Speed – Pump Overspeed
Issue description
The urea pump is operating at a speed that exceeds the expected range, which may indicate a malfunction in the system controlling the pump's operation.
Check the cause
The urea pump speed sensor
The wiring and connections to the urea pump
The control signals from the dosing control unit
Repair steps
Inspect
Inspect the urea pump speed sensor for damage or misalignment.
Check
Check the wiring and connections to the urea pump for continuity and proper seating.
Verify
Verify the control signals from the dosing control unit to the urea pump using the appropriate diagnostic tool.
Parts you might need