19307
New Holland 19307 – DCU: Urea Pressure Too High
Issue description
The system has detected that the urea pressure is above the acceptable threshold, indicating a potential issue with the urea system's pressure regulation.
Check the cause
Urea tank pressure sensor
Urea pump operation
Urea line blockage or restriction
Repair steps
Inspect the urea tank pressure sensor for proper installation and connection.
Check the operation of the urea pump to ensure it is functioning correctly.
Examine the urea lines for any blockages or restrictions that may be causing excessive pressure.
Parts you might need
(0)Get help to fix this fault by requesting a quote