New Holland 19370 – DCU: Urea pressure too low during commissioning with pump motor error
Issue description
During the system startup or 'commissioning' phase, the DEF (Diesel Exhaust Fluid / Urea) pump is failing to build the required pressure. The system attempts to prime the lines, but the pressure remains too low, either because the pump motor is physically not delivering fluid, there is an air leak in the suction line, or the pump motor is experiencing an electrical/mechanical error.
Applies to these machines
9 machines- T6 Series
- T7 Series
- T8 Series
- T9 Series
- CR Series
- CR9090
- CX Series
- CX8090
- LM Series Telehandlers
Check the cause
Check the DEF tank level to ensure it is adequately filled, as an empty tank prevents pressure buildup
Inspect DEF quality for signs of contamination or crystallization in the tank
Visually inspect all DEF lines, fittings, and the pump module for external leaks
Inspect the DEF filter element on the pump module for blockages caused by debris or crystallized urea
Examine the electrical harness and connectors leading to the DEF pump module for damage, corrosion, chafing, or loose connections
Use a diagnostic scan tool to monitor live DEF pressure data and perform a manual activation test of the DEF pump
Repair steps
Address basic faults
Correct any simple issues found during the diagnostic checks, such as filling the DEF tank or repairing damaged wiring.
Replace DEF filter
As a first-line repair attempt, replace the DEF module's filter element to resolve potential blockages.
Clear codes and test
Use a diagnostic tool to clear all related fault codes from the DCU. Initiate the SCR system's commissioning procedure (self-test) to allow the DEF system to prime and build pressure.
Replace DEF supply module
If fault code 19370 returns after replacing the filter and running the commissioning test, the DEF pump itself has likely failed. Replace the entire DEF Supply Module.
Program new module
If the DEF Supply Module was replaced, perform the required software installation or programming procedure using the official CNH diagnostic tool. The manufacturer may require evidence of prior troubleshooting before providing the necessary software passwords.
Parts you might need
(5)- DEF Supply Module84246892
Complete pump and control unit assembly (Bosch Denoxtronic 2.2). Bosch part number: 0444022021.
- DEF Module Filter Element84254852
Replaceable filter located on the supply module.
- DEF Module Filter Cap Repair Kit47401714
Contains the cap for the filter housing.
DEF/Urea Pump Module (Remanufactured)
5802513624RRemanufactured part number for the urea injection module.
DEF/Urea Pump Module (Bosch)
0 444 022 021Corresponding Bosch part number for the module.
Get help to fix this fault by requesting a quote