New Holland 19599 – New Holland Dosing Control Unit Dcu: CAN Receive Signal Error: Torque Driver Demand Not in Range

Issue description

The system has detected an issue with the CAN receive signal, specifically that the torque driver demand is not within the expected range. This may affect the proper operation of the dosing control unit.

Check the cause

  1. The integrity of the CAN communication wiring between the Dosing Control Unit and the source of the torque driver demand signal

  2. The functionality of the component sending the torque driver demand signal

  3. The configuration and settings of the Dosing Control Unit related to CAN signal processing

Repair steps

  1. Inspect

    Inspect the CAN communication wiring for damage, corrosion, or loose connections.

  2. Test

    Test the component sending the torque driver demand signal to ensure it is functioning correctly.

  3. Verify

    Verify the configuration and settings of the Dosing Control Unit related to CAN signal processing.