New Holland 19739 – ECM: ECM Power Relay Shut Off Too Late

Issue description

The main power relay for the Engine Control Module (ECM) or Powertrain Control Module (PCM) is not de-energizing at the correct time. The control module monitors the power relay's control circuit and has detected that the circuit voltage remains high when it should be off. This indicates that the relay is stuck in the closed position or the control circuit is shorted to a voltage source, causing continuous power supply to the ECM even after the ignition key is turned off. This condition can lead to improper power management, a drained battery, or prevent the control module from properly completing its power-down sequence.

Applies to these machines

  • T7030
  • T7.220
  • T7.315

Check the cause

  1. Visually inspect the battery terminals for tightness and corrosion, and inspect the ECM/PCM power relay socket in the fuse box for signs of water ingress, melted plastic, or darkened, corroded terminals.

  2. Inspect all fuses related to the ECM and ignition circuits for blown fuses (on a T7030, the fuse box is located behind a panel on the right-hand control console).

  3. Verify the alternator is not overcharging the system by checking battery voltage with a multimeter with the engine off (~12.6V) and running (should not exceed 15V).

  4. Perform a relay swap test by exchanging the main relay with an identical, known-good relay from a non-critical circuit (like the horn or work lights) within the same fuse box.

Repair steps

  1. Locate the Main Relay

    Find the main power relay (often labeled 'Ignition Relay') in the fuse box. On T7 series tractors, this is typically located behind a panel on the right-hand control console.

  2. Test the Relay Circuit

    With the ignition OFF, remove the relay. Check for continuity between terminals 30 and 87a (if it is a 5-pin relay) and an open circuit between 30 and 87. Next, bench test the relay by applying 12V power and a ground to the coil terminals (85 and 86). The relay should click, and there should be near-zero resistance between terminals 30 and 87. Replace the relay if it fails these tests.

  3. Inspect the Wiring Harness

    If the relay tests good, visually inspect the wiring harness between the fuse box and the ECM for chafing, rubbing, or heat damage. Using a multimeter, check the control pin socket (terminal 85 or 86) in the fuse box with the key off. It should read 0 volts. If voltage is present, trace and repair the short to power in the harness.

  4. Check the ECM Connection

    Inspect the main electrical connector at the ECM. Look for bent or corroded pins and ensure the connector is securely seated.

  5. Final Verification

    Clear the fault codes from the control module and perform a test drive or run cycle. If the code persists after verifying the relay and wiring are good, suspect an internal failure of the ECM (least common cause).

Parts you might need

(5)
  • Verify correct relay with dealer using machine serial number

  • Replaces 82017871. Listed for T7.220 models

  • 12V, 20A Micro Relay

    90338514

    Replaces 84543528. Listed for T7.315 crank circuit

  • Replaces 87341931. Listed for T7.315 start circuit

  • Relay box for ISO micro-relays

    87301875

    Listed for T7030

Get help to fix this fault by requesting a quote

Browse other New Holland codes