New Holland 19748 – New Holland Dosing Control Unit Dcu: Too high urea temperature in pump module or leakage test failed
Issue description
The fault code indicates that the urea temperature in the pump module is too high or that a leakage test has failed, triggering an emergency shut off. This is related to the temperature sensor of the pump module detecting an out-of-range condition.
Check the cause
The temperature sensor of the pump module
The pump module for signs of overheating or damage
The integrity of the urea system for leaks
Repair steps
Inspect the temperature sensor of the pump module
Check for physical damage or improper installation.
Verify the operation of the temperature sensor of the pump module
Use a diagnostic tool to confirm the sensor's readings match expected values.
Check the pump module for overheating or damage
Look for signs of excessive heat or physical damage that could cause the temperature to rise.
Inspect the urea system for leaks
Perform a visual inspection of the urea lines and connections for any signs of leakage.
Parts you might need
(0)Get help to fix this fault by requesting a quote