New Holland 19748 – New Holland Dosing Control Unit Dcu: Too high urea temperature in pump module or leakage test failed

Issue description

The fault code indicates that the urea temperature in the pump module is too high or that a leakage test has failed, triggering an emergency shut off. This is related to the temperature sensor of the pump module detecting an out-of-range condition.

Check the cause

  1. The temperature sensor of the pump module

  2. The pump module for signs of overheating or damage

  3. The integrity of the urea system for leaks

Repair steps

  1. Inspect the temperature sensor of the pump module

    Check for physical damage or improper installation.

  2. Verify the operation of the temperature sensor of the pump module

    Use a diagnostic tool to confirm the sensor's readings match expected values.

  3. Check the pump module for overheating or damage

    Look for signs of excessive heat or physical damage that could cause the temperature to rise.

  4. Inspect the urea system for leaks

    Perform a visual inspection of the urea lines and connections for any signs of leakage.