19802

New Holland 19802 – DCU: Urea Tank Temp Implausible with Pump Temp

Issue description

The Dosing Control Unit (DCU) has detected a significant and implausible difference between the temperature readings from the urea (DEF) tank and the DEF pump module. This discrepancy triggers a communication timeout related to the temperature sensor over the CAN bus (often associated with a P0600 serial communication link fault), meaning the control unit cannot trust the temperature data required for proper Selective Catalytic Reduction (SCR) system operation.

Applies to these machines

  • T7.220
  • T7.235
  • T7.250
  • T7.260
  • T7.270

Check the cause

  1. Reboot the system by turning the tractor completely off, waiting a few minutes, and restarting to see if the fault is intermittent

  2. Check battery voltage and ground connections, as low voltage or poor grounds can cause communication errors between modules

  3. Inspect the wiring harness and connectors for the urea tank temperature/level sensor and the DCU for damage, corrosion, loose pins, moisture intrusion, or chafing

  4. Check for actual overheating issues by verifying if the coolant lines to the DEF tank are warm or hot when they shouldn't be (ensure the DEF tank heater Coolant Control Valve is not stuck open)

  5. Monitor live data using a diagnostic tool to compare urea tank temperature, pump module temperature, and ambient temperature for plausibility

  6. Perform basic sensor voltage checks at the connector with the ignition on (e.g., 4.6 - 5.2 V for the urea tank temperature sensor)

  7. Inspect CAN bus communication wiring between the DCU and the urea tank sensor for integrity

Repair steps

  1. Repair wiring and connections

    If issues are found with the battery, grounds, or wiring, clean corroded terminals, tighten loose connections, and repair damaged wires. Clear fault codes and re-test.

  2. Replace urea tank sensor

    If the temperature sensor is identified as faulty, drain the DEF tank to a low level, disconnect the electrical connector, unscrew the combined sensor unit from the top of the tank, install the new sensor ensuring a proper seal, and refill the tank.

  3. Replace Dosing Control Unit (DCU)

    If all other diagnostic steps fail to resolve the issue, replace the DCU. This requires software installation and programming by an authorized dealer, as CNH may not issue the necessary passwords for programming unless proper troubleshooting has been performed and documented.