New Holland 19805: Urea Tank Temperature - Open Circuit
Issue description
The system has detected an open circuit in the urea tank temperature monitoring circuit. This may prevent proper monitoring of the urea tank temperature, potentially affecting system performance or safety.
Check the cause
The wiring and connections related to the urea tank temperature sensor
The integrity of the circuit from the sensor to the controller
The sensor itself for damage or failure
Repair steps
Inspect
Inspect the wiring and connections associated with the urea tank temperature sensor for damage, corrosion, or disconnection.
Test
Test the continuity of the circuit from the sensor to the controller to identify any breaks or open connections.
Replace
If a fault is found in the wiring or sensor, replace the affected component as needed.
Parts you might need
(0)Get help to fix this fault by requesting a quote