19805
New Holland 19805 – New Holland Dosing Control Unit Dcu: Urea Tank Temperature Not Plausible with Pump Module Temperature
Issue description
The urea tank temperature is not plausible compared to the pump module temperature. The raw value of the urea temperature is too high, indicating a potential issue with the temperature sensor in the tank.
Check the cause
tank temperature sensor
pump module temperature sensor
wiring to the tank temperature sensor
Repair steps
Inspect
Inspect the tank temperature sensor for physical damage or corrosion.
Test
Test the tank temperature sensor for proper operation using a multimeter.
Check
Check the wiring and connections to the tank temperature sensor for shorts or open circuits.
Parts you might need
(0)Get help to fix this fault by requesting a quote