New Holland 19808: Unreliable Temperature Data in Urea Tank
Issue description
The temperature data in the urea tank is unreliable, as the diagnostic temperature value of the urea is too low. The temperature sensor in the tank is reporting a value that is outside the acceptable range.
Check the cause
the temperature sensor in the tank (reagent temperature - solution in the tank)
the pump unit temperature
the connection or wiring to the temperature sensor in the tank
Repair steps
Inspect
Inspect the temperature sensor in the tank (reagent temperature - solution in the tank) for damage or contamination.
Test
Test the temperature sensor in the tank (reagent temperature - solution in the tank) to verify its functionality.
Check
Check the connection and wiring to the temperature sensor in the tank (reagent temperature - solution in the tank) for any faults.
Parts you might need
(0)Get help to fix this fault by requesting a quote