19808

New Holland 19808: Unreliable Temperature Data in Urea Tank

Issue description

The temperature data in the urea tank is unreliable, as the diagnostic temperature value of the urea is too low. The temperature sensor in the tank is reporting a value that is outside the acceptable range.

Check the cause

  1. the temperature sensor in the tank (reagent temperature - solution in the tank)

  2. the pump unit temperature

  3. the connection or wiring to the temperature sensor in the tank

Repair steps

  1. Inspect

    Inspect the temperature sensor in the tank (reagent temperature - solution in the tank) for damage or contamination.

  2. Test

    Test the temperature sensor in the tank (reagent temperature - solution in the tank) to verify its functionality.

  3. Check

    Check the connection and wiring to the temperature sensor in the tank (reagent temperature - solution in the tank) for any faults.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other New Holland codes