New Holland 19813 – DCU: Urea Pressure Too Low During Operation or Dosing

Issue description

The Selective Catalytic Reduction (SCR) system has detected that the Diesel Exhaust Fluid (DEF) pressure is below the required target of 71 to 90 psi (4.9 to 6.2 bar) during operation. The system relies on the DEF pump to pressurize the fluid so the dosing injector can atomize it into the exhaust stream. Low pressure prevents proper dosing, which can lead to reduced engine power, dashboard warnings, and eventually prevent the engine from starting.

Applies to these machines

  • T6
  • T7
  • T8
  • TS6
  • CR
  • CX
  • Magnum
  • Puma
  • Farmall
  • Maxxum
  • Optum
  • Steiger
  • Windrowers
  • Sprayers
  • Telehandlers
  • Combines

Check the cause

  1. Check DEF level and quality (fluid should be crystal clear with a faint ammonia smell; concentration should be 31.8% to 33.2% via refractometer)

  2. Inspect all DEF lines and fittings between the tank, pump, and dosing module for leaks, kinks, cracks, or restrictions

  3. In cold climates, verify that the DEF in the tank and lines is not frozen

  4. Perform a Urea Dosing System Test (UDST) using the Electronic Service Tool (EST) to monitor system pressure (target is 71.1 to 89.9 psi / 4900 to 6200 millibar)

  5. Check with a dealer for any available software updates for the engine and after-treatment control modules

Repair steps

  1. Address Fluid and Basic Issues

    If DEF is low, contaminated, or frozen, resolve this first. Refill the tank with high-quality DEF. If contaminated, drain and flush the tank with distilled water before refilling.

  2. Repair Leaks

    Repair or replace any damaged DEF lines or fittings found during the visual inspection.

  3. Clear Clogged Filters

    Access the DEF pump module, remove the old filter cartridge, and install a new one to clear potential clogs (the most common cause of low pressure).

  4. Address Dried Pump Filter (after replacement)

    If a new DEF pump has been installed and fails to build pressure, the internal filter may be dry. Allow the pump to sit submerged in DEF overnight to re-saturate the filter, then re-run the system leak test multiple times.

  5. Test the Dosing Injector

    If pressure seems adequate but the fault persists, remove the dosing injector from the exhaust (keep connected electrically/hydraulically) and run a dosing quantity test. A 2-minute test should yield 40-55ml. A poor spray pattern or incorrect volume indicates a clogged or faulty injector.

  6. Replace Faulty Components

    If the system fails to build pressure during the UDST and no leaks or clogs are found, replace the DEF pump/supply module (may require programming). If diagnostic pressure readings are erratic compared to a manual gauge, replace the DEF pressure sensor. If a suction leak is present at the tank pickup, replace the WEMA unit.