19817
New Holland 19817 – New Holland Dosing Control Unit Dcu: Plausibility of UDV Stuck – P202F Reagent – Dosing Valve – Blocked (Only Stuck Closed)
Issue description
The fault code indicates that the UDV (urea dosing valve) is likely stuck in a closed position, preventing the proper dosing of reagent. This condition may affect the system's ability to function correctly.
Check the cause
UDV (urea dosing valve) position
UDV (urea dosing valve) operation
presence of blockage in the dosing valve
Repair steps
Inspect
Inspect the UDV (urea dosing valve) for signs of blockage or mechanical obstruction.
Test
Test the UDV (urea dosing valve) operation to confirm if it is stuck in a closed position.
Clean or Replace
If the UDV (urea dosing valve) is found to be blocked or stuck, clean or replace it as necessary.
Parts you might need
(0)Get help to fix this fault by requesting a quote