New Holland 2024 – TCM: Transmission Clutches Not Calibrated

Issue description

The transmission clutches are not calibrated, which affects the proper operation of the machinery. This fault occurs when the Transmission Control Module (TCM) memory lacks the necessary calibration data for clutch engagement. This typically happens after a new transmission controller has been installed, following service or replacement of transmission components, or if the calibration data has been otherwise lost. A calibration routine must be performed to allow the system to learn the engagement points of the clutches.

Applies to these machines

  • TM Series
  • TM165
  • 60 Series
  • 8260
  • 8560
  • T7000 Series
  • Genesis 70 Series
  • G170
  • 8670
  • T8.xxx Series
  • T4
  • T5
  • T7
  • T8

Check the cause

  1. Verify there are no other active fault codes, as they must be resolved before calibration can be successfully performed

  2. Ensure the tractor is stationary with a wheel speed of 0 KPH/MPH

  3. Check that the parking brake is applied (an error code will be displayed if the handbrake is not engaged)

  4. Ensure the shuttle lever/gear position is in neutral

  5. Verify the transmission oil temperature is within the specific required range (e.g., at or above 120°C for some models)

  6. Set the engine speed to the specified RPM (typically around 1200 RPM)

Repair steps

  1. Enter Calibration Mode

    With the parking brake on, enter calibration mode. For TM/60 Series: press and hold both the upshift and downshift buttons while starting the engine. For Genesis 70 Series: move the shift lever to the neutral downshift position and hold it to the left while turning the key to the 'on' position. The display should show 'CC'.

  2. Verify Conditions

    Check the display for the transmission oil temperature. Ensure the oil is at the correct temperature and the engine is set to the specified RPM (e.g., 1200 +/- 50 RPM).

  3. Initiate Calibration

    Move the shuttle lever to the forward position.

  4. Calibrate Individual Clutches

    Use the upshift button to cycle through and select the clutch to be calibrated (e.g., A, B, C, D, E). Press and hold the downshift button to begin calibrating. Continue holding until the calibration value is displayed, then release the downshift button to save the value.

  5. Complete the Sequence

    Repeat the calibration step for all required clutches. After the final clutch is calibrated, the display may show 'CF' to indicate a successful calibration.

  6. Exit and Save

    Turn the engine off and wait for about 10 seconds to store the new calibration values in the controller.

  7. Restart and Verify

    Start the engine normally. Verify that fault code 2024 is no longer present.