2072
New Holland 2072 – New Holland Transmission: Reverse Switch Input Shorted to +12 Volts or 5 Volt Reference
Issue description
The reverse switch input from the FNRP pod is experiencing a short to +12 volts or the FNRP pod 5 volt reference. This condition can cause incorrect operation of the reverse function or related systems.
Check the cause
Reverse switch input wiring
FNRP pod 5 volt reference circuit
FNRP pod wiring and connections
Repair steps
Inspect
Inspect the wiring and connections for the reverse switch input and the FNRP pod.
Test
Test the reverse switch input for a short to +12 volts or the FNRP pod 5 volt reference using a multimeter.
Repair
If a short is found, repair or replace the affected wiring or connections.
Parts you might need
(0)Get help to fix this fault by requesting a quote