2073

New Holland 2073: Shuttle Lever Reverse Switch Voltage Too Low

Issue description

The voltage from the Shuttle Lever Reverse Switch is below the expected level, which may affect the proper operation of the machine's transmission system.

Check the cause

  1. Shuttle Lever Reverse Switch

  2. Wiring to the Shuttle Lever Reverse Switch

  3. Power supply to the Shuttle Lever Reverse Switch

Repair steps

  1. Inspect

    Inspect the Shuttle Lever Reverse Switch for physical damage or wear.

  2. Test

    Test the voltage output of the Shuttle Lever Reverse Switch using a multimeter.

  3. Check

    Check the wiring and connections to the Shuttle Lever Reverse Switch for looseness, corrosion, or damage.

  4. Verify

    Verify the power supply to the Shuttle Lever Reverse Switch is functioning correctly.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other New Holland codes