2336

New Holland 2336 – TCM: Additional Reducers Creeper Not Engaging

Issue description

The Transmission Control Module (TCM) has detected a failure in the engagement of the additional reducers creeper gear system. When the operator attempts to activate the creeper function, the system does not confirm that the creeper gear has successfully engaged. This fault can be triggered by mechanical, hydraulic, or electrical issues that prevent the creeper mechanism from operating as commanded.

Applies to these machines

  • T4
  • T5
  • T6
  • T7
  • T7030
  • T7.220
  • T7.230
  • T7.250
  • TM
  • TM155
  • TS

Check the cause

  1. Verify correct operator procedure for engaging the creeper gear (engine running, shuttle lever in neutral, and clutch/brake pedals depressed before activating the switch)

  2. Check transmission fluid level and condition, as low or contaminated fluid can cause engagement problems

  3. Inspect the diagnostic display for other active fault codes, specifically those related to the creeper potentiometer (2338, 2339) or creeper solenoid (2351, 2361)

  4. Use diagnostic 'H' routines (accessed via diagnostic test switch Tool No. 4FT 950) to verify the functionality of the creeper engagement switch (H5) and sensor inputs (H9)

  5. Test the creeper solenoid by checking for 12V power at the harness connector (with key on and switch activated) and measuring the coil resistance for an open or short circuit

  6. Test the creeper potentiometer by measuring its resistance (connecting probes to the center wiper terminal and one outer terminal) while manually engaging/disengaging the creeper; resistance should change smoothly without sudden jumps or dropouts

  7. Visually inspect the mechanical creeper control shift linkage (cables, rods, levers) for signs of damage, binding, or incorrect adjustment

  8. Perform hydraulic pressure testing at the transmission test ports to ensure sufficient pressure is available to engage the clutch packs or actuators (advanced diagnostic)

Repair steps

  1. Address electrical faults

    If the creeper solenoid is faulty, disconnect the electrical connector, remove retaining bolts/clips, install the new solenoid, and ensure O-rings/seals are seated. If the potentiometer is faulty, disconnect wiring, remove from mounting, install the new one, and ensure correct alignment with the creeper mechanism. If the engagement switch is faulty, remove the console panel to replace it. Repair any damaged wiring or corroded connectors.

  2. Repair mechanical linkage

    If the shift linkage is bent, broken, or out of adjustment, repair or replace the affected cables, rods, levers, or bushings.

  3. Address internal transmission damage

    If external electrical and mechanical components are functioning properly but the creeper still will not engage (or hydraulic pressure is low), major internal transmission service by a qualified technician may be required to inspect for worn gears or clutch packs.

  4. Clear codes and calibrate

    After replacing any components, clear all fault codes using the diagnostic menu (HC routine) or a diagnostic tool. Perform a transmission calibration if recommended by the service manual, especially after replacing major components or if clutch-related codes were present.

  5. Test operation

    Test the creeper gear engagement and disengagement multiple times to ensure the repair was successful.

Parts you might need

(3)
  • Alternative part number 87723774. Fits T-series tractors including T6 and T7 models (e.g., T7030, T7.220, T7.250).

  • Supersedes 82012603, 82017351, 82021036, 82033385, 87559692, 82010303. Fits T4, T5, T6, T7, TM, and TS series. A parts diagram for the T7.230 shows this component as part of the creeper sensor assembly.

  • Specific to TM155. For other models, refer to specific parts diagrams for cables, rods, levers, clevises, and bushings.

Get help to fix this fault by requesting a quote