2346

New Holland 2346: Electromagnetic Valve Clutch 2R Circuit Fault

Issue description

A short circuit to 'ground' or an open circuit has been detected in the electromagnetic valve clutch 2R circuit. This condition may prevent the proper operation of the affected component.

Check the cause

  1. Electromagnetic valve clutch 2R circuit wiring

  2. Connections related to the electromagnetic valve clutch 2R circuit

  3. The component identified by this code

Repair steps

  1. Inspect

    Inspect the wiring of the electromagnetic valve clutch 2R circuit for damage, wear, or improper connections.

  2. Test

    Test the electromagnetic valve clutch 2R circuit for continuity and proper insulation using a multimeter.

  3. Repair

    Repair or replace any damaged wiring or connections found during inspection and testing.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other New Holland codes