2351

New Holland 2351: Electromagnet of the Speed Reducer - Open Circuit or Short Circuit to Ground

Issue description

The electromagnet of the speed reducer is experiencing an open circuit or a short circuit to ground. This condition prevents the electromagnet from functioning properly, which may affect the operation of the speed reducer.

Check the cause

  1. The wiring connections to the electromagnet of the speed reducer

  2. The integrity of the wiring harness leading to the electromagnet of the speed reducer

  3. The electromagnet of the speed reducer for physical damage or wear

Repair steps

  1. Inspect

    Inspect the wiring connections to the electromagnet of the speed reducer for looseness, corrosion, or damage.

  2. Test

    Test the wiring harness leading to the electromagnet of the speed reducer for continuity and insulation integrity.

  3. Replace

    If damage or failure is found, replace the electromagnet of the speed reducer as needed.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other New Holland codes