2351

New Holland 2351: Short Circuit of the Electromagnetic Valve of the 1F Clutch to the +12 V Power Source When the Drive Is Off

Issue description

A short circuit has been detected in the electromagnetic valve of the 1F clutch, specifically when the drive is off. This condition involves an unintended electrical connection between the electromagnetic valve and the +12 V power source.

Check the cause

  1. The electromagnetic valve of the 1F clutch

  2. Wiring connected to the electromagnetic valve of the 1F clutch

  3. Connections between the electromagnetic valve of the 1F clutch and the +12 V power source

Repair steps

  1. Inspect

    Inspect the electromagnetic valve of the 1F clutch for visible damage or wear.

  2. Test

    Test the wiring connected to the electromagnetic valve of the 1F clutch for continuity and insulation integrity.

  3. Check

    Check the connections between the electromagnetic valve of the 1F clutch and the +12 V power source for looseness or corrosion.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other New Holland codes