New Holland 2352: Short Circuit of the Electromagnetic Valve of the Clutch 1M to +12 V Voltage Source with the Drive Off
Issue description
A short circuit has been detected in the electromagnetic valve of the clutch 1M, where it is connected to the +12 V voltage source even when the drive is off. This condition may cause improper operation of the clutch system or damage to related components.
Check the cause
The electromagnetic valve of the clutch 1M
The wiring and connections to the electromagnetic valve of the clutch 1M
The +12 V voltage source and its connection to the electromagnetic valve of the clutch 1M
Repair steps
Inspect
Inspect the electromagnetic valve of the clutch 1M for visible damage or signs of short circuit.
Test
Test the wiring and connections to the electromagnetic valve of the clutch 1M for continuity and proper insulation.
Verify
Verify the +12 V voltage source and its connection to the electromagnetic valve of the clutch 1M to ensure it is not causing the short circuit.
Parts you might need
(0)Get help to fix this fault by requesting a quote