2353
New Holland 2353: Short Circuit of the Clutch Solenoid of Even Gears to +12V Voltage Source
Issue description
A short circuit has been detected in the clutch solenoid of even gears, where current is flowing to the +12V voltage source with the drive turned off. This indicates an electrical fault in the affected circuit.
Check the cause
Clutch solenoid of even gears
Wiring connected to the clutch solenoid of even gears
Connections to the +12V voltage source
Repair steps
Inspect
Inspect the clutch solenoid of even gears for visible damage or wear.
Test
Test the wiring connected to the clutch solenoid of even gears for continuity and insulation integrity.
Check
Check the connections to the +12V voltage source for corrosion, looseness, or damage.
Parts you might need
(0)Get help to fix this fault by requesting a quote