2368

New Holland 2368 – TCU: Low Range Clutch Not Calibrated

Issue description

The low range clutch within the transmission has not been properly calibrated. The Transmission Control Unit (TCU) has not learned the necessary pressure and timing required to engage the low range clutch pack smoothly, which negatively affects transmission performance in low range. This fault is also triggered when a new, uncalibrated controller is installed.

Applies to these machines

  • T7 Series
  • T8 Series
  • TM Series
  • TM115
  • TM120
  • TM125
  • TM130
  • TM135
  • TM140
  • TM150
  • TM155
  • TM165
  • TM175
  • TM190
  • 60 Series
  • 8160
  • 8260
  • 8360
  • 8560
  • Genesis 70 Series
  • G170
  • 8670

Check the cause

  1. Check for other active fault codes (e.g., clutch pedal potentiometer, speed sensors, solenoid open/short circuits) and resolve them first, as they will prevent calibration

  2. Ensure transmission oil temperature is between 10°C and 60°C (50°F and 140°F). Warm up the tractor if 'CL' is displayed, or let it cool if 'CH' is displayed

  3. Verify the tractor is parked on level ground with the park brake engaged

  4. Ensure the operator is seated in the seat to satisfy the operator presence switch

  5. Check that all hydraulic levers and the shuttle lever are in the neutral position

Repair steps

  1. T7 Series Calibration - Enter Calibration Mode

    Ensure the tractor is on level ground and the park brake is on. With the engine off, press and hold both the upshift and downshift buttons. Start the engine, then release the buttons. The display should show the transmission oil temperature or 'CAL'.

  2. T7 Series Calibration - Perform Calibration

    Set the engine speed to approximately 1200 RPM. Depress the clutch pedal, move the shuttle lever to the forward position, and then release the clutch pedal. Press the auto-shift button for an automatic calibration. The display will show the clutches being calibrated in sequence (e.g., A, B, C) and will display 'END' or 'CF' when complete. Turn the engine off and wait for at least 10 seconds to allow the controller to store the new calibration values.

  3. T8 Series Calibration - Enter Calibration Mode

    With the tractor running, access the diagnostic menu by pressing and holding the 'PROG' button while turning the key on. Navigate to the 'TCU' (Transmission Control Unit) menu and find the transmission setup or calibration option (often 'ETC').

  4. T8 Series Calibration - Perform Calibration

    Follow the on-screen prompts, which will include setting the engine RPM (around 1100 RPM), and engaging the shuttle lever to forward after pressing the clutch. The system will then calibrate the clutches. When finished, the display will indicate completion. Turn the tractor off to save the values.

  5. Genesis / 60 Series Calibration - Enter Calibration Mode

    With the engine off, move the shift lever to the neutral downshift position and hold it to the left while turning the key on and starting the engine. On some models, you may need to release the lever as soon as the dash lights up. 'CC' on the display indicates calibration mode.

  6. Genesis / 60 Series Calibration - Perform Calibration

    Set the engine RPM to 1200 RPM. Push the shifting lever forward to make 'CC' flash. The tractor will then calibrate the clutches. After completion, stop the engine and wait 10 seconds before restarting.