2381

New Holland 2381: Circuit Break or Short Circuit on +BAT of the Rotational Speed Sensor of the 5th Gear Shaft

Issue description

A fault has been detected in the electrical circuit related to the +BAT power supply of the rotational speed sensor for the 5th gear shaft. This could be due to a break or a short circuit in the wiring or connections associated with this component.

Check the cause

  1. The wiring and connections related to the +BAT power supply of the rotational speed sensor of the 5th gear shaft

  2. The integrity of the circuit for the rotational speed sensor of the 5th gear shaft

Repair steps

  1. Inspect

    Inspect the wiring and connections related to the +BAT power supply of the rotational speed sensor of the 5th gear shaft for any signs of damage, wear, or disconnection.

  2. Test

    Test the circuit for the rotational speed sensor of the 5th gear shaft to identify any breaks or short circuits.

  3. Repair

    Repair or replace any damaged wiring, connections, or components identified during the inspection and testing.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote