2903

New Holland 2903: Voltage of the Torque Sensor Power Supply is Below Allowable Level

Issue description

The voltage supplied to the torque sensor is below the minimum acceptable level of 4.8 V. This may affect the proper operation of the torque sensor and the system it is part of.

Check the cause

  1. Power supply circuit for the torque sensor

  2. Connections to the torque sensor

  3. Voltage output at the source of the power supply

Repair steps

  1. Verify the voltage output at the power supply source

    Use a multimeter to measure the voltage at the power supply source to ensure it meets the required level.

  2. Inspect the wiring and connections to the torque sensor

    Check for loose, damaged, or corroded connections that may be causing a voltage drop.

  3. Test the power supply circuit

    Ensure the circuit is functioning properly and delivering the correct voltage to the torque sensor.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other New Holland codes