New Holland 3107: Fuel Flow Meter - Short Circuit to Battery
Issue description
A short circuit has been detected in the fuel flow meter circuit, specifically to the battery. This condition may cause improper fuel flow measurement and affect engine performance.
Check the cause
Fuel flow meter wiring
Fuel flow meter connections
Battery circuit integrity
Repair steps
Inspect
Inspect the wiring and connections of the fuel flow meter for damage, wear, or improper routing.
Test
Test the fuel flow meter circuit for continuity and insulation resistance using a multimeter.
Repair
Repair or replace any damaged wiring or connections found during inspection.