3119

New Holland 3119 – Engine: ECM 12V Sensor Supply Voltage Low

Issue description

The Engine Controller detects a low voltage condition on the 12V sensor supply circuit. This may affect the proper operation of sensors connected to this power source.

Check the cause

  1. ECM 12V Sensor Supply Voltage

  2. Wiring and connections to the affected circuit

Repair steps

  1. Check the voltage

    Measure the voltage at the ECM 12V sensor supply to confirm it is within the expected range.

  2. Inspect wiring

    Examine the wiring and connections associated with the ECM 12V sensor supply for damage, corrosion, or loose contacts.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other New Holland codes