New Holland 3131 – ECU: Grid Heater Always Switched On
Issue description
The Engine Control Module (ECM) has detected that the grid heater is drawing power when it has not been commanded to do so. The grid heater is designed to activate only under specific cold temperature conditions (typically below -1.5°C to -3°C) to warm intake air for improved starting. Continuous activation outside of normal pre-heat and post-heat cycles leads to excessive energy consumption and potential damage to the heating element and its related components.
Applies to these machines
29 machines- T6010
- T6020
- T6030
- T6040
- T6050
- T6060
- T6070
- T7
- TS115A
- L180
- L185
- L190
- LS180.B
- LS185.B
- LS190.B
- 430
- 435
- 440
- C185
- C190
- 440CT
- 445CT
- 450CT
- D75
- D85
- D95
- DC75
- DC85
- DC95
Check the cause
Verify operating conditions: The grid heater should only activate at low temperatures (e.g., below -3°C/26.6°F). If active at warmer temperatures, a fault is present.
Check for related fault codes such as 3154 (Short Circuit to Battery), 3155 (Short Circuit to Ground), or 3156 (No Load/Open Circuit) to help pinpoint the electrical fault.
Inspect the grid heater relay (solenoid) to see if it is stuck in the closed (on) position. Try removing the relay to see if it deactivates the heater.
Test the grid heater circuit: With the key off, measure resistance between the power terminal and ground (should be close to 0 ohms). With the key on, check for 12 volts at the power terminal to determine if voltage is from a stuck relay or a short.
Inspect the wiring harness for the grid heater and relay for damage, chafing, or short circuits, particularly a short to ground on the ECM control wire.
Repair steps
Isolate the fault
Disconnect the grid heater relay. If the heater deactivates, the problem is likely with the relay or its control circuit. If the heater remains on, there is likely a short circuit in the main power wiring to the heater.
Replace the grid heater relay
If the relay is identified as mechanically stuck or internally shorted, replace it with a new OEM part.
Repair wiring
If a short circuit or other wiring issue is found, repair the damaged section of the harness and ensure all connections are clean and secure.
Check the ECM
If the relay and wiring are in good condition, the ECM may be continuously sending the activation signal. Have a qualified technician diagnose the ECM using specialized tools.
Clear fault codes
After completing repairs, clear the fault codes from the ECM and run the machine to ensure fault code 3131 does not reappear.
Parts you might need
(13)Grid Heater Power Relay
47565510OEM part
Solenoid Switch
87406968Listed for LS180.B
- Relay86619908
Included in grid heater kit
- Grid Heater Element82017872
OEM part
- Grid Heater Kit718203094
May include heater, relay, gaskets, and wiring
Grid Heater Kit
87397276May include heater, relay, gaskets, and wiring
Gasket
86014151For LS180.B
Gasket
5802950329Included in grid heater kit
Grid Heater Relay Wiring Harness (T7 Series)
47679309Fits T7.165S, T7.175, T7.190, T7.210, T7.225 Tier 4B
Cold Start Grid Heater Relay Wire Harness (Construction)
87519664Grid Heater Relay
47783139Supersedes older part numbers for AutoCommand Tier 4B models
Grid Heater Element
2854837Heater, Tor
- Heater Control/Accessory Relay86529089
12V, 20/30A. Listed for various New Holland skid steer and compact track loaders (C175, C185, C190). May be a control relay rather than the main high-current solenoid.
Get help to fix this fault by requesting a quote