New Holland 3131 – ECU: Grid Heater Always Switched On

Issue description

The Engine Control Module (ECM) has detected that the grid heater is drawing power when it has not been commanded to do so. The grid heater is designed to activate only under specific cold temperature conditions (typically below -1.5°C to -3°C) to warm intake air for improved starting. Continuous activation outside of normal pre-heat and post-heat cycles leads to excessive energy consumption and potential damage to the heating element and its related components.

Applies to these machines

  • T6010
  • T6020
  • T6030
  • T6040
  • T6050
  • T6060
  • T6070
  • T7
  • TS115A
  • L180
  • L185
  • L190
  • LS180.B
  • LS185.B
  • LS190.B
  • 430
  • 435
  • 440
  • C185
  • C190
  • 440CT
  • 445CT
  • 450CT
  • D75
  • D85
  • D95
  • DC75
  • DC85
  • DC95

Check the cause

  1. Verify operating conditions: The grid heater should only activate at low temperatures (e.g., below -3°C/26.6°F). If active at warmer temperatures, a fault is present.

  2. Check for related fault codes such as 3154 (Short Circuit to Battery), 3155 (Short Circuit to Ground), or 3156 (No Load/Open Circuit) to help pinpoint the electrical fault.

  3. Inspect the grid heater relay (solenoid) to see if it is stuck in the closed (on) position. Try removing the relay to see if it deactivates the heater.

  4. Test the grid heater circuit: With the key off, measure resistance between the power terminal and ground (should be close to 0 ohms). With the key on, check for 12 volts at the power terminal to determine if voltage is from a stuck relay or a short.

  5. Inspect the wiring harness for the grid heater and relay for damage, chafing, or short circuits, particularly a short to ground on the ECM control wire.

Repair steps

  1. Isolate the fault

    Disconnect the grid heater relay. If the heater deactivates, the problem is likely with the relay or its control circuit. If the heater remains on, there is likely a short circuit in the main power wiring to the heater.

  2. Replace the grid heater relay

    If the relay is identified as mechanically stuck or internally shorted, replace it with a new OEM part.

  3. Repair wiring

    If a short circuit or other wiring issue is found, repair the damaged section of the harness and ensure all connections are clean and secure.

  4. Check the ECM

    If the relay and wiring are in good condition, the ECM may be continuously sending the activation signal. Have a qualified technician diagnose the ECM using specialized tools.

  5. Clear fault codes

    After completing repairs, clear the fault codes from the ECM and run the machine to ensure fault code 3131 does not reappear.

Parts you might need

(13)
  • Grid Heater Power Relay

    47565510

    OEM part

  • Solenoid Switch

    87406968

    Listed for LS180.B

  • Relay86619908

    Included in grid heater kit

  • OEM part

  • May include heater, relay, gaskets, and wiring

  • Grid Heater Kit

    87397276

    May include heater, relay, gaskets, and wiring

  • Gasket

    86014151

    For LS180.B

  • Gasket

    5802950329

    Included in grid heater kit

  • Grid Heater Relay Wiring Harness (T7 Series)

    47679309

    Fits T7.165S, T7.175, T7.190, T7.210, T7.225 Tier 4B

  • Cold Start Grid Heater Relay Wire Harness (Construction)

    87519664
  • Grid Heater Relay

    47783139

    Supersedes older part numbers for AutoCommand Tier 4B models

  • Grid Heater Element

    2854837

    Heater, Tor

  • 12V, 20/30A. Listed for various New Holland skid steer and compact track loaders (C175, C185, C190). May be a control relay rather than the main high-current solenoid.

Get help to fix this fault by requesting a quote

Browse other New Holland codes